Call Us!
Products & Services
 
Services

We are committed to providing you with a “One Call Does it All” central service center.

Please call us for your no charge service review proposal.
1-800-383-0477


Fire Alarms

We are proud distributors of state of the art Notifier Fire Alarm Systems and service all major brands.

Inspection Frequency: Annually
Code Reference: NFPA 72

  • Upon completion of each individual device inspection (a trademark service of A-1 Fire and Electric Company), an additional report listing deficient devices along with respective repair prices is provided.

  • Personnel training about your system as well as upgrade suggestions are always offered to our customers as part of our premium service.

  • We offer 24 hour a day, 7 day a week UL/FM listed monitoring of your Fire Alarm system.
Smoke Dampers:
Inspection Frequency: Annually
Code Reference: NFPA 105
Fire Dampers:
Inspection Frequency: Annually
Code Reference: NFPA 80

Click here to fill-in our online Service Request Form

Back to top

Fire Sprinkler Systems

Inspection Frequency: Annually, semiannually or quarterly as required.
Code Reference: NFPA 13

Fire Pumps: Annual inspection & flow test of fire pump.
Fire Pump Controllers: Annual inspection & testing of fire pump controller/transfer switch.
Back Flow Preventers: Annual inspection, testing & certification.
Fire Hydrants: Annual flow testing & certification.
Standpipe Systems: Annual, semiannual or quarterly inspection as required.

Additional Services:
Micro Biological Testing (MIC) of water within Fire Sprinkler & Standpipe Systems.

  • Upon completion of each individual device inspection (a trademark service of A-1 Fire and Electric Company), an additional report listing deficient devices along with respective repair prices is provided.

  • 24 hours, 7 day a week service.

Click here to fill-in our online Service Request Form

Back to top

Electrical Services

A-1 Fire and Electric Company provides fully licensed electrical contracting services. Our licensed Master & Journeyman Electricians offer exceptional electrical service, 24 hours a day, 7 days a week. Call today for your free estimate.

Some of our specialty services include:

  • Full Service Fleet.
  • New Construction & Renovation.
  • Complete Electrical Service on all Interior & Exterior equipment, lighting and wiring.
  • Fuse Panel & Service upgrades.
  • Indoor & Outdoor lighting services.
  • Bucket Truck Services.
  • Fire Suppression Systems interlock.
  • Smoke Detectors.
  • Emergency & Exit lights.
  • Generators & Emergency systems.
  • Fire Pump controller inspections and repairs.
  • Annual Infrared inspections.
  • Motor wiring & repairs.
  • Control wiring.
  • Elevator electrical upgrades.

Click here to fill-in our online Service Request Form

Back to top

Fire Alarm Monitoring

The same company that presently services your Fire Alarm can now also be the company that provides you affordable 24 hour a day, 7 day a week UL/FM listed monitoring.

Monitoring Flow Chart
Fire Alarm Fire Alarm Elevators
A device on your property goes off, indicating a fire. The Fire Alarm panel indicates a “TROUBLE” light”. An elevator passenger picks up the elevator telephone in the event of emergency.
The monitoring company is alerted and dispatches the Fire Department IMMEDIATELY. The monitoring company is alerted and calls A-1 Fire and Electric Company immediately, as well as the managers on the customer-provided list if instructed. The passenger speaks to a live operator at the monitoring company, available 24 hours a day, 7 days a week.
The monitoring company calls the managers on a customer-provided list, as well as A-1 Fire and Electric Company if desired. A-1 Fire and Electric Company calls the manager on duty to report that there is trouble on your Fire Alarm. The monitoring company contacts A-1 Fire and Electric Company.
 
  A-1 Fire and Electric Company dispatches a technician or creates a proposal to repair any problems with the Fire Alarm. A-1 Fire and Electric Company calls the designated persons and/or companies on a customer-provided list.

Click here to fill-in our online Service Request Form

Back to top

Fire Alarm Runner Service

As of September 14th, 2009, all properties in Miami Dade County with an existing Fire Alarm and Fire Sprinkler system will be required to obtain a UL/FM Fire Alarm Runner Service maintenance contract with a certified Fire Alarm company. This code will require any property with a Fire Alarm/Sprinkler System to enter into a contract with a Licensed/Certified Fire Alarm Contractor to provide “Runner Service” with a maximum two (2) Hour response time.

The Code can be found at the following link:
http://www.municode.com/resources/gateway.asp?pid=10620&sid=9
See Chapter 14, Article III, Sections 14-66 & 14-67.

A1 Fire and Electric Company is pleased to offer you this service and keep you compliant with all necessary code requirements.

Click here to fill-in our online Service Request Form

Back to top

Automatic Fire Suppression Systems

We are proud to service all major brands.

Inspection Frequency: Semi-Annually
Code Reference: NFPA 17, 17A, 96

Recharges:
On an as needed-basis, units are recharged with appropriate chemicals, checked for leakage and placed back into service.

6 Year Maintenance:
Every 6 years, wet chemical and various parts to be changed to ensure proper performance in case of fire.

12 Year Hydro Test:
Checks integrity of cylinder and replacement agents.

24/7:
24 hour, 7 day a week emergency service to ensure your kitchen system is put back into service immediately.

Click here to fill-in our online Service Request Form

Back to top

Fire Extinguishers

We are proud to service all major brands.

Inspection Frequency: Annually
Code Reference: NFPA 10

Recharges:
On an as-needed basis, units are recharged with appropriate chemicals, checked for leakage and placed back into service.

6 Year Maintenance:
Every 6 years chemicals and miscellaneous parts are changed to ensure proper performance.

12 Year Maintenance:
Every 12 years, both the above and a pressure test of the cylinder are performed to ensure integrity.

Click here to fill-in our online Service Request Form

Back to top

Emergency & Exit Lights

We sell and service all major brands:

  • Beghelli
 

Inspection Frequency: Annually
Code Reference: NFPA 101

Click here to fill-in our online Service Request Form

Back to top

Smoke/Duct Detectors

We sell and service all major brands:

  • Amseco
  • System Sensor


Smoke Detectors:
Inspection Frequency: Annually
Code Reference: NFPA 101

Duct Detector “Smoke Bomb” Test:
Inspection Frequency:
Annually
Code Reference: NFPA 90A

Smoke Dampers:
Inspection Frequency: Annually
Code Reference: NFPA 105

Fire Dampers:
Inspection Frequency: Annually
Code Reference: NFPA 80

Click here to fill-in our online Service Request Form

Back to top

Emergency Generators

Inspection Frequency: Quarterly (Yearly inspection schedule requires 4 visits: 3 no-load tests and 1 load test).
Code Reference: NFPA 101, 110

  • 24 hour, 7 day a week emergency service.

  • Personnel training about your system, along with upgrade suggestions are always offered to our customers as part of our premium service.

Click here to fill-in our online Service Request Form